Audited by an independent third-party inspection agency
5V12A---A good helper for 3C battery test
Side air intake on the right side
With the 1/3 of the side area occupied, and slender air intake design, it can reflect the visual aesthetics of modern industial design.
Square air outlet
Compared to 5V6A equipment, 5V12A uses two fans for heat dissipation. Specifications:
Project index |
Parameter index |
|
Input Power |
AC110V/220V±10% / 60Hz |
|
Resolution |
AD 16bit;DA 16bit |
|
Input Resistance |
≥1MΩ |
|
Input Power |
826W |
|
Channel Features |
Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure |
|
Channel Control Mode |
Independent Control |
|
Voltage |
Constant voltage control range |
25mV-5V |
DischargeMin Voltage |
2V |
|
Accuracy |
0.05% of FS |
|
Stability |
0.05% of FS |
|
Current |
Output of per channel |
Range 1:5mA-1A;Range 2:1A-6A; Range 3:6A-12A |
Accuracy |
0.05% of FS |
|
Cut-off current of CV |
Range 1:2mA;Range 2:12mA; Range 3:24mA |
|
Stability |
0.05% of FS |
|
Power |
Per Channel Output Power |
60W |
Stability |
± 0.1% of FS |
|
Time |
Rise Time |
1ms (10%FS- 90% FS) |
Step Time Range |
Single Step Time Range≤365*24 h, Time Form Support 00:00:00.000(h,min,s,ms) |
|
Data Recording |
Record Condition |
Time t:100ms |
Voltage U:10mV |
||
Current I:Range 1:2mA;Range2 :12mA;Range3 :24mA |
||
Record Frequency |
10Hz |
|
Charge |
Charge Mode |
Constant Current Charge,Constant Voltage Charge, Constant Current and Constant Voltage,Constant Power Charge |
End Conditon |
Voltage,Current,Relative Time,Capacity,- V |
|
Discharge |
Discharge Mode |
Constant Current Discharge,Constant Power Discharge,Constant Resistance discharge |
End Condition |
Voltage,Current,Relative Time,Capacity |
|
Pulse |
Charge |
CCC,CPC |
Discharge |
CCD,CPD |
|
Minimum Pulse Width |
500ms |
|
Pulse |
32 pulse setting in one step |
|
Automated Switch |
Automated switch from charge to discharge for each pulse |
|
Cycle |
Loop Measure Range |
1~65535 times |
Max Steps Per Loop |
254 |
|
Nested Loop |
Nested loop Function,Max Support 3 Layers |
|
Protection |
Software Protection |
Power-down Data Protection |
Setting Protection Condition,Setting Parameter:Low Voltage limit,Upper Voltage limit,Low Current limit,Upper Current limit,Delay Time |
||
Voltage and Current Testing Sample |
4-wire connecting |
|
Noise |
<85dB |
|
Data Management |
MYSQL Database |
|
Communication Means |
TCP/IP Protocol |
|
Data Output |
EXCEL,TXT |
|
Communication Interface |
Ethernet Port |
|
Per Unit Main Channels No. |
8 |
|
Dimensions |
3U(19"),483*563*130(-S1) |
Please contact us to get more detailed specifications.