Customization: | Available |
---|---|
Type: | Li-ion Battery |
Cathode Material: | NCM |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
To meet the various requirements adopted in advanced battery research, our equipments can automatically switch the current range in accordance with user settings to maintain consistent accuracy, and can be fitted with additional hardware to provide a number of optional features and capabilities. The model CT-4008-5V6A can be configured with multi-current range channels, which have a current control range of 0.5mA to 0.1A, 0.1A to 3A, 3A to 6A as standard. The accuracy for current and voltage on these channels is ±0.05% FS.
5V6A |
0.5mA~0.1A |
0.1A~3A |
3A~6A |
Please contact us to get more detailed specifications.
Project index |
Parameter index |
|
Input Power |
AC110V/220V ±10% / 50Hz |
|
Resolution |
AD:16bit;DA:16bit |
|
Input Resistance |
≥1MΩ |
|
Input Power |
425W |
|
Channel Features |
Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure |
|
Channel Control Mode |
Independent Control |
|
Voltage |
Constant voltage control range |
25mV-5V |
DischargeMin Voltage |
1.0V(with cylinder spring clamp) |
|
Accuracy |
± 0.05% ofFS |
|
Stability |
± 0.05% of FS |
|
Current |
Output of per channel |
Range1:0.5mA~0.1A;Range2:0.1A~3A Range3:3A~6A |
Accuracy |
± 0.05% of FS |
|
Cut-off current of CV |
Range1:0.2mA;Range2:6mA;Range3:12mA |
|
Stability |
± 0.05% of FS |
|
Power |
Per Channel Output Power |
30W |
Stability |
± 0.1% of FS |
|
Time |
Rise Time |
The Current 10%-90% Hardware Response Time is 1ms |
Step Time Range |
Single Step Time Range≤365*24 h, Time Form Support 00:00:00.000(h,min,s,ms) |
|
Data Recording |
Record Condition |
Time t:100ms |
Voltage U:10mV |
||
Current I:Range1:0.2mA;Range2:6mA;Range3:12mA |
||
Record Frequency |
10Hz |
|
Charge |
Charge Mode |
Constant Current Charge,Constant Voltage Charge, Constant Current and Constant Voltage, ChargeConstant Power Charge |
End Conditon |
Voltage,Current,Relative Time,Capacity,- V |
|
Discharge |
Discharge Mode |
Constant Current Discharge,Constant Power Discharge,Constant Resistance discharge |
End Condition |
Voltage,Current,Relative Time,Capacity |
|
Pulse |
Charge |
CCC,CPC |
Discharge |
CCD,CPD |
|
Minimum Pulse Width |
500ms |
|
Pulse |
32 pulse setting in one step |
|
Automated Switch |
Automated switch from charge to discharge for each pulse |
|
Cycle |
Loop Measure Range |
1~65535 times |
Max Steps Per Loop |
254 |
|
Nested Loop |
Nested loop Function,Max Support 3 Layers |
|
Protection |
Software Protection |
Power-down Data Protection |
Setting Protection Condition,Setting Parameter:Low Voltage limit,Upper Voltage limit,Low Current limit,Upper Current limit,Delay Time |
||
Voltage and Current Testing Sample |
4-wire connecting |
|
Noise |
<85dB |