Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | 2 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
CT-4000-mA battery testing system for coin cell
High efficiency in cooling system. The picture below shows us the intake system on the left side.
New cooling system is much safer and higher efficiency than before. As we know, air inlet occupies the half of the left and right sides. It is really in excellent industrial design. Use it, it can give you a suprise.
5V10mA |
5μA~1mA |
1mA~5mA |
5mA~10mA |
5V20mA |
10μA~1mA |
1mA~10mA |
10mA~20mA |
5V50mA |
25μA~1mA |
1mA~25mA |
25mA~50mA |
Popularizing multi-range technology actively
To meet the various requirements adopted in advanced battery research, our equipments can automatically switch the current range in accordance with user settings to maintain consistent accuracy, and can be fitted with additional hardware to provide a number of optional features and capabilities.
Small in size. Big on capability.
You can see equipment's unite ID via LCD. What's more, 164 port is used to connect accessories to test coin cells. CT-4000-mA equipment has already became the classic equipment, which is widely used in universities, laboratories and research institutes.
High efficiency in cooling system. The picture below shows us the intake system on the left side.
New cooling system is much safer and higher efficiency than before. As we know, air inlet occupies the half of the left and right sides. It is really in excellent industrial design. Use it, it can give you a suprise.
Turn back! You can't just see the cool system.
On the back, you can see the RS-485 interface and AC power supply, which connect the middle computer and BTS server via the netting twine.
Project index |
Parameter index |
|
Input Power |
AC 110V/220V ±10% / 50Hz |
|
resolution |
AD:16bit;DA:16bit |
|
Input Resistance |
≥1GΩ |
|
Input Power |
25W |
|
Channel Features |
Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure |
|
Channel Control Mode |
Independent Control |
|
Voltage |
Per Channel Control Voltage Range |
25mV~5V |
Minimum discharge voltage |
-5V |
|
Accuracy |
± 0.05% of FS |
|
Stability |
± 0.05% of FS |
|
Current |
Per Channel Current Range |
Range 1:5uA~1mA;Range 2:1mA~10mA;Range 3:10mA~20mA |
Cut-off current of CV |
0.04mA |
|
Accuracy |
± 0.05% of FS |
|
Stability |
± 0.05% of FS |
|
Power |
Per Channel Output Power |
0.1W |
Stability |
± 0.1% of FS |
|
Time |
Current Response Time |
1ms (0-Full Range) |
Step Time Range |
≤(365*24 )hour/step, Time Form Support 00:00:00(h,min:s,ms) |
|
Data Recording |
Record Condition |
Time t:100ms |
Voltage U:10mV |
||
Current I:Range 1:2uA;Range 2:20uA;Range 3:40uA |
||
Record Frequency |
10Hz |
|
Charge |
Charge Mode |
Constant Current Charge,Constant Voltage Charge, Constant Current and Constant Voltage Charge,Constant Power Charge |
End Conditon |
Voltage,Current,Relative Time,Capacity |
|
Discharge |
Discharge Mode |
Constant Current Discharge,Constant Power Discharge,Constant Resistance Discharge |
End Condition |
Voltage,Current,Relative Time,Capacity |
|
DCIR test supported |
||
Pulse Test |
Charge |
Constant Current Charge,Constant Power Charge |
Discharge |
Constant Current Discharge,Constant Power Discharge |
|
Minimum Pulse Width |
500ms |
|
Pulse Number |
32 diffirent pulse for a single step |
|
Charge And Discharge Switch |
continuous switched for a single pulse step |
|
End Condition |
Voltage,Relative Time |
|
Cycle |
Loop Measure Range |
1~65535 times |
Max Steps Per Loop |
254 |
|
Nested Loop |
Nested loop Function,Max Support 3 Layers |
|
Protection |
Software Protection |
Power-down Data Protection |
Off-line Testing Function |
||
Setting Protection Condition,Setting Parameter:Low Voltage limit,Upper Voltage limit,Low Current limit,Upper Current limit,Delay Time |